Actual source readings
Enter GH and KH for both tap and RO water, including residual hardness in your RO supply.
Prepare a batch to a GH or KH target. See how much tap and RO water to mix and the resulting hardness of both parameters.
Enter both sources and one hardness target, then calculate the quantities. A single mixing ratio sets both GH and KH.
The blend is for prepared water. Final aquarium readings depend on the water already in the tank. pH depends on buffering, CO2, and other water chemistry. Confirm both hardness readings, condition tap water as required, and match the batch to your livestock and existing aquarium.
Enter GH and KH for both tap and RO water, including residual hardness in your RO supply.
Target GH or KH and check how the same proportion changes the other parameter.
Prepare the batch in liters, US gallons, or UK gallons and see the tap/RO percentages.
Replacement-water preparation
The calculator estimates a new batch of water from two measured sources. It does not model the aquarium after a partial water change or choose livestock targets.
Tap fraction = (target − RO reading) ÷ (tap reading − RO reading), using the selected hardness parameter. Tap volume = batch volume × tap fraction; RO volume is the remainder. Resulting GH and KH each equal tap reading × tap fraction + RO reading × RO fraction.
This is a volume-weighted mixing estimate using consistent hardness units and additive volumes. It assumes no remineralizer addition, precipitation, or other reaction changes the mixture. Mix and test the actual batch to confirm it.
With tap water at GH 12 and KH 8, and measured RO at GH 0 and KH 0, select GH and target 6. The tap fraction is 6 ÷ 12 = 0.5: mix 20 L tap water with 20 L RO. The batch is predicted to have GH 6 and KH 4.
If your RO instead measures GH 2 and KH 1, keeping the GH 6 target needs 40% tap and 60% RO: 16 L tap plus 24 L RO. Resulting KH is 3.8. These examples show why entering residual RO hardness matters; they are not universal water targets.
Two source waters provide one adjustable ratio. In the first example, GH 6 requires 50% tap, which also sets KH to 4. A KH target of 2 would instead need 25% tap and would give GH 3. Both desired numbers can be met together only when they correspond to the same ratio.
A target outside the two source readings cannot be reached by mixing alone. If both source readings for the selected parameter are equal, every ratio gives that value; a matching target is ambiguous and a different target is unreachable. The tool asks you to target the other parameter or review the sources.
Use measured source readings and the required hardness for your actual livestock. The output describes prepared replacement water; the aquarium also contains its remaining old water and may have active substrate or other influences.
Do not average source pH numbers or expect this blend to set aquarium pH. Buffering and CO2 affect pH. Check the prepared water, condition it as needed, and avoid abrupt changes in the aquarium.
FAQ
Enter your measured values. The example uses zero explicitly, but the calculator accepts residual GH and KH in the RO source.
Only when both targets require the same tap/RO ratio. Choose one in the calculator and inspect the predicted value for the other.
No. It calculates the prepared batch only. The remaining tank water and any subsequent chemistry also affect final aquarium readings.
Yes. A target equal to one source reading can produce that endpoint when the sources differ. That mathematical result is not a recommendation to use pure RO for your livestock.
No. pH is not a volume-weighted hardness measurement. The calculator does not predict pH.
Related aquarium planning
Use the calculator result with logs, guides, and maintenance tools so one number becomes part of a repeatable aquarium care routine.
Cookies & analytics
We use cookies to understand how Aquarium Tracker is used. You can decline non-essential tracking and the site will keep working.